Header band, 2800 x 400 (7:1), WebP or JPG, under 160 KB. NOT A NEW PHOTOGRAPH: crop this band out of the middle of the same camera original as this discipline's portrait master, from the full-size file rather than the delivered 1200 x 1800 — the uploader refuses anything narrower than 1400 px. Flat exposure, nothing above 60% luminance, no lens flare, and the subject sitting in the middle third so the type above it has clean ground. NO LEGIBLE VESSEL NAME, IMO NUMBER OR CLIENT BRANDING.

01

Fire Fighting Appliances (FFA)

Fire Fighting Appliances is the inspection, servicing, refilling, pressure testing and certification of a vessel's fire systems — extinguishers, fixed CO₂, foam, the fire main, breathing apparatus and detection. Most falls due annually under the guidelines SOLAS II-2 Reg. 14 requires be followed — A.951(23) §9.1, MSC.1/Circ.1432 §7 and MSC.1/Circ.1318/Rev.1 §5; extinguisher bodies, propellant cartridges and CO₂ cylinders are tested hydrostatically at ten years, steel SCBA cylinders at five. It is done by personnel competent for the system. We work the scope in one attendance where the stay allows, and hand back the records, certificates and inventory.

What we do

Portable and wheeled extinguishers

  • Annual inspection of every unit — tag, seal, charge and body condition
  • Recharge and refill: water, foam, dry powder and CO₂ units
  • Five-yearly test discharge of portable units in a drill, then recharge and reseal
  • Ten-yearly hydrostatic testing of extinguisher bodies and propellant cartridges
  • Replacement units can be supplied and entered on the appliance inventory

Fixed extinguishing systems

  • Fixed CO₂ — cylinder contents checked by weighing or level indication
  • CO₂ distribution pipework, flexible hoses, release lines and alarms tested
  • Ten-yearly hydrostatic test of the CO₂ cylinders — a 10% sample rising on failure, and every cylinder before the 20-year anniversary and at each 10-year anniversary after
  • Fixed foam — proportioner testing and concentrate sampling for laboratory analysis
  • Water-mist, sprinkler and deluge — section testing, pump and nozzle checks
  • Fixed dry chemical powder, typically gas carriers — powder, propellant and pipework, two-yearly

Fire main, hoses and pumps

  • Fire hoses pressure tested at maximum fire main pressure — every length inside the five-year cycle, each identified by its own number
  • Nozzles, couplings, hydrants and applicators inspected, function tested and renewed
  • Failed lengths can be replaced where the replacement is supplied with the job
  • Emergency fire pump — starting arrangement, suction lift and delivery pressure
  • International shore connection — presence, condition, gasket, bolts and stowage location

Breathing apparatus and outfits

  • SCBA — annual service, function test, low-pressure warning and demand valve
  • SCBA cylinders — five-yearly hydrostatic test for steel; others per the Administration
  • Breathing-air compressor output sampled and analysed against EN 12021
  • EEBD — inspection, expiry control, replacement and disposal of expired units
  • Firefighter's outfits — suits, helmets, boots, gloves, lifelines and lamps inspected

Detection, closing appliances, documents

  • Fixed fire detection and alarm loops — functional testing, zone by zone
  • Portable gas detectors and explosimeters calibrated against certified span gas
  • Fire dampers and ventilation closing appliances — operation and closure tested
  • Quick-closing valves — remote and local operation tested, then reset
  • Fire control plan checked against the appliances actually fitted on board
  • Fire-fighting appliance inventory reconciled, corrected and reissued
  • Crew's weekly, monthly and quarterly records verified against the Reg. 14 maintenance plan

Regulatory basis

The instruments that govern this work, cited as a superintendent would write them. What each one requires of the shipowner — not what we sell.

SOLAS Ch. II-2Construction — fire protection, fire detection and fire extinction (SOLAS 1974, as amended)

Fire protection systems, fire-fighting systems and appliances must be kept in good order and ready for immediate use, and a discharged portable extinguisher must be recharged or replaced with an equivalent unit immediately. Maintenance, testing and inspection are carried out on the basis of guidelines developed by the Organization, under a maintenance plan kept on board (Reg. 14.2).

FSS CodeInternational Code for Fire Safety Systems (IMO Res. MSC.98(73), as amended)

Sets the specification each fire safety system must meet — extinguishers, fixed gas, foam, water-spraying and sprinkler systems, fire detection, breathing apparatus. Equipment must remain to the specification against which it was approved.

MSC.1/Circ.1432 as amended by MSC.1/Circ.1516Revised guidelines for the maintenance and inspection of fire protection systems and appliances, as amended by MSC.1/Circ.1516 (sprinkler system and water quality items)

Provides the minimum recommended level of maintenance and inspection behind the SOLAS II-2/14.2.2.1 plan: weekly to ten-yearly items for fire mains, hoses, fixed gas, foam, water-mist, powder, detection and breathing apparatus. It does not cover portable extinguishers or fixed CO₂.

IMO Res. A.951(23)Improved Guidelines for Marine Portable Fire Extinguishers

Guidelines for portable extinguishers: service at intervals not exceeding one year; test discharge of one extinguisher of each type manufactured in the same year every five years, in a drill; hydraulic testing of extinguishers and propellant cartridges every ten years.

MSC.1/Circ.1318/Rev.1Revised guidelines for the maintenance and inspections of fixed carbon dioxide fire-extinguishing systems (supersedes MSC.1/Circ.1318)

The minimum recommended maintenance for fixed CO₂ systems under SOLAS II-2/14.2.1.2: 30-day visual checks (§4), annual inspection (§5), cylinder contents verified against a 90% charge threshold biennially or at survey (§6.1.1), internal inspection of all control valves every five years (§7), and hydrostatic testing of high-pressure cylinders at intervals not exceeding ten years — a 10% sample at the 10-year inspection, but every cylinder before the 20-year anniversary and at each 10-year anniversary after that (§6.1.2).

SOLAS Reg. I/8 · SOLAS Reg. I/7Surveys of life-saving appliances and other equipment of cargo ships (I/8); surveys of passenger ships (I/7)

Cargo ships of 500 gross tonnage and upwards: annual survey within three months of the anniversary date, a periodical survey at the second or third anniversary, and renewal within five years (I/8). Passenger ships take a renewal survey once every 12 months (I/7); the Passenger Ship Safety Certificate itself is issued for not more than 12 months (I/14).

Intervals

What is due, how often, and which instrument sets the period. Where an interval comes from the manufacturer or from class rather than from an IMO instrument, the table says so.

Survey and service intervals for Fire Fighting Appliances (FFA)
ItemIntervalSet byNote
Portable and wheeled fire extinguishers — inspectionAnnualIMO Res. A.951(23), §9.1 (portable) · MSC.1/Circ.1432, §7.12 (wheeled)safety clip, pressure indicator, weight against full charge, hose and nozzle; powder units inverted
Fire extinguishers — five-year service5-yearlyIMO Res. A.951(23), §9.1.1 (portable) · MSC.1/Circ.1432, §9.6 (wheeled)one of each type manufactured that year: portables test discharged in a drill, wheeled examined
Extinguisher bodies and propellant cartridges — hydrostatic test10-yearlyIMO Res. A.951(23), §9.1.2 (portable) · MSC.1/Circ.1432, §10.5 (wheeled)to the recognised standard or maker's instruction; date stamped on the body; failures replaced
Fixed CO₂ system — annual inspectionAnnualMSC.1/Circ.1318/Rev.1, §5boundary openings, containers, piping, nozzles, manifold, flexible hoses, entrance doors, warning signs
Fixed CO₂ cylinders — contents verified by weighing2-yearly ±3 months (passenger ships); at each intermediate, periodical or renewal survey (cargo ships)MSC.1/Circ.1318/Rev.1, §6.1.1cylinders below 90% of nominal charge are refilled
Fixed CO₂ cylinders — hydrostatic test, hose renewal10-yearlyMSC.1/Circ.1318/Rev.1, §6.1.2at least 10% internally inspected and hydrostatically tested at the 10-year inspection, 50% if one fails and all if further cylinders fail; and all cylinders before the 20-year anniversary and at every 10-year anniversary after that
Fixed foam, water-mist and sprinkler systems — testAnnual; foam concentrate control tests not more than 3 years after supply and every year thereafter — protein-based alcohol-resistant concentrates before delivery and annually from the startMSC.1/Circ.1432, §7.4 and §7.5 · MSC.1/Circ.1312, §5 (concentrate)concentrate sampled aboard, analysed ashore; proportioners tested to +30/-10% at five years (§9.2.4)
Fire main, pumps, hydrants, nozzles and hosesAnnual; every hose length pressure tested within 5 yearsMSC.1/Circ.1432, §7.1hose sample tested at maximum fire main pressure; emergency fire pump and shore connection checked
Fixed fire detection and alarm — functional testAnnualMSC.1/Circ.1432, §7.2gas detection carries no interval here — the detector maker's schedule and flag or class apply
Breathing apparatus, breathing-air quality and EEBDAnnualMSC.1/Circ.1432, §7.8 and §7.8.1face masks and demand valves checked, recharging air analysed against EN 12021; gauges weekly (§4.5)
SCBA cylinders — hydrostatic test5-yearly (steel cylinders)MSC.1/Circ.1432, §9.4aluminium and composite to the satisfaction of the Administration; retest date stamped on the cylinder
Fire dampers and ventilation closing appliances — remote operation testAnnualMSC.1/Circ.1432, §7.6.1 (fire dampers, remote operation) · §7.6.3 (ventilation controls interconnected with fire-protection systems)each damper operated from its remote position and reset; local damper operation is quarterly (§6.3). Firefighter's outfits carry no annual interval in MSC.1/Circ.1432 — §5.5 is a monthly check that the outfit locker is complete and serviceable — and engine-room quick-closing valves fall outside the circular; both are worked to the maker's schedule and to flag or class requirements
Safety equipment surveys — cargo and passenger shipsCargo: annual ±3 months, periodical at the 2nd or 3rd anniversary, renewal ≤5 years · Passenger: 12-monthlySOLAS Reg. I/8 (cargo ships, 500 GT and over) · SOLAS Reg. I/7 (passenger ships)the survey itself is carried out by the flag Administration or its Recognised Organisation — this row is the deadline the service work is planned against, not a survey we perform; the periodical survey takes the place of that year's annual survey
Discharged extinguisher; any system not immediately readyImmediatelySOLAS II-2/14.2 — operational readinessrecharged or replaced with an equivalent unit; alternative cover in place while work is in hand

What you receive

  • FFA attendance report and a service certificate for each system serviced — signed by the attending technician and countersigned on board, naming vessel, IMO number, port, date and the instrument the work was carried out against
  • Fire extinguisher service record and inspection tag for every unit, and, for each pressure vessel landed for hydrostatic test, the test facility's own certificate passed through to you — naming the facility that performed and stamped the test, the test date and the stamped retest date
  • Fixed CO₂, foam, water-mist, sprinkler and fixed detection test report — cylinder by cylinder, section by section and zone by zone, with readings recorded rather than a pass mark, plus the foam concentrate laboratory analysis against the periodical control tests
  • Fire hose and hydrant pressure test record — every length identified by its own number, the test pressure applied, pass or fail, and the lengths replaced
  • SCBA service record per set, cylinder retest certificate, breathing-air analysis against EN 12021, and EEBD and firefighter's outfit records unit by unit
  • Calibration certificate for each portable gas detector and explosimeter, naming the span gas used, that gas's own certificate reference and the calibration date — a record of the check performed against that gas. We publish no accreditation scope for this work, so where your flag, class or charterer requires calibration under an accredited scope, say so at enquiry and we will tell you in writing whether we can document it
  • Fire-fighting appliance inventory reconciled against the fire control plan, and the defect and recommendation list handed over on board before we leave, with any replacement parts quoted
  • Every record dated and carrying its next due date, in a form that files straight into the SOLAS II-2 Reg. 14 maintenance plan — the full pack as signed PDFs within five working days of the team leaving the vessel, and within 24 hours where the vessel sails before then or a certificate expires before then, provided you tell us at the order that the date is tight. A certificate is issued only for what passed: where an item fails, the defect list goes out on that same clock and the certificate for that item follows the re-test. Cylinders landed for hydrostatic test run on their own clock — that facility's certificate reaches you when the test house issues it. Copies and reissues come from docs@shipcertify.com.

Where

Attendance is planned from the nearest of 6 service bases to any of the 299 ports in the published index, around the clock. If your port is not listed, ask — the index is what we publish, not the limit of where we mobilise.

Open the port index

Questions we are actually asked

Are you approved for my flag?

We publish no authorisation scopes on this site, and no approval certificates — read nothing here as a claim either way. Tell us the flag, the vessel and the scope. Whatever documentation applies to that work is supplied in writing with the quotation — granting entity, scope, reference, and the register you check it on. Where we cannot document the scope for your flag, we say so before you award.

Can you get it all done inside an 18-hour port stay?

Send ETA, ETD, berth and scope. We attend from the nearest of six bases — Istanbul, Izmir, Iskenderun, Varna, Constanta, London — and say what fits the window before you commit. Where the stay is short we split by what the certificate needs first. Time on board for a full FFA scope — every extinguisher, the fire main, hoses and nozzles, detection, SCBA sets, fixed systems and dampers — with two technicians, boarding to landing: a coaster, tug or general cargo ship under about 10,000 GT, 8 to 12 hours; a bulk carrier, tanker or container ship of about 10,000 to 50,000 GT, 14 to 20 hours; above 50,000 GT, 20 to 30 hours, which we run as two shifts or with a third technician to bring it inside one stay. A passenger ship or ro-pax is quoted on the extinguisher and detection-zone count rather than banded. What moves those hours is the number of extinguishers and detection zones, not the deadweight — and cargo work over a protected space, which holds the fixed-system tests until it stops. Cylinders landed for hydrostatic test do not come back inside the same stay. Vessel alongside: 24/7 hotline +90 532 657 48 78.

Will class and PSC accept your certificate?

Acceptance turns on two things: that whoever does the work holds the authorisation your surveyor asks for, and that the record shows what was done. Neither is ours to guarantee on a surveyor's behalf. We publish no authorisation scopes here. Tell us the flag, class society and scope; whatever documentation applies is sent with the quotation, to check on the grantor's public register before you award — and where we cannot document the scope your surveyor asks for, we say so before you award rather than let you assume it. The report carries instrument, interval, unit-by-unit results and defects.

What happens if you find something that fails?

It goes on the defect list with the reason and the instrument it fails against, and you are told on board, not in an email a week later. Parts and consumables required during the service can be supplied with the job, quoted and invoiced against the same attendance. What can actually be fitted before we leave, and what has to be ordered, depends on the item and the port — we tell you which it is on board rather than leaving you to find a second vendor. Which makes and types can be put on board is answered against your equipment list rather than from a stock list published here, because a stock position printed on a website is stale the week after it is written: send the appliance inventory with the scope sheet — make, type, capacity and the date stamped on each unit — and the quotation states, item by item, what can be on board for that attendance, which base it comes from, and what has to be ordered, with the documentation each item carries. Spares: spares@shipcertify.com.

Which cylinders go for hydrostatic test, and do they leave the ship?

Portable extinguisher bodies and propellant cartridges at ten years. On a fixed CO₂ bank, at least 10% at the ten-year inspection, rising to 50% then all if any fail — and under MSC.1/Circ.1318/Rev.1 every cylinder goes for test before the 20-year anniversary and at each 10-year anniversary after that. Steel SCBA cylinders run on five years (MSC.1/Circ.1432 §9.4); aluminium and composite to the satisfaction of the Administration. Hydrostatic testing is a workshop operation — cylinders are landed and returned. They go to a facility competent to perform and stamp the test; the quotation names that facility before the work starts, and its own certificate is passed through to you unaltered rather than restated on ours. Plan on 5 to 10 working days from landing to return alongside at a port served from one of our own bases — Istanbul, Izmir, Iskenderun, Varna, Constanta, London — and 10 to 15 working days where the cylinders move through the partner network from a port without a base, or where export and re-import formalities apply to a pressure vessel. The quotation gives the figure for your named port. A fixed CO₂ bank is the long pole: cylinders emptied for test have to be refilled, weighed and refitted before the system is back in service. Where the vessel sails first, tell us at the order which port to return them to and they are held and delivered on a later call.

The Safety Equipment Certificate survey is due. What do you need from us?

The last service records for each system, the fire control plan, the appliance inventory, and the survey date and port. We work the scope against what the surveyor will open — expiry dates, hydrostatic test stamps, foam analysis dates, SCBA cylinder dates — and give you the defect list before the surveyor writes one.

Makes and types we service

The equipment actually found on ships, indexed by category, with the corporate history a superintendent needs — a plate still says Norsafe, Schat-Harding, Germanischer Lloyd. This is what the work covers. It is not a list of approvals: maker authorisation is granted per make and per type, and ours is supplied in writing with a quotation.

185 of 185 makes

Portable and wheeled extinguishers

25
GLORIAGLORIAGermany
LALIZASLALIZASGreece
DafoDafoSweden
NAFFCONAFFCOUnited Arab Emirates
  • UnitorWilhelmsen Ships Service · NorwayShipboard extinguishers, CO2, foam and powder; Unitor is Wilhelmsen's marine brandAcquired
  • KiddeKidde Global Solutions · United StatesExtinguishers and marine systems; left Carrier for Lone Star Funds in December 2024Acquired
  • BadgerKidde Global Solutions · United StatesUS extinguisher brand, now inside Kidde Global Solutions alongside Kidde and EdwardsAcquired
  • AmerexMcWane · United StatesUS portable and wheeled extinguishers; owned by the McWane groupAcquired
  • AnsulJohnson Controls · United StatesExtinguishers, dry chemical and foam; Tyco brand carried into Johnson ControlsAcquired
  • Buckeye Fire EquipmentUnited States
  • MinimaxMinimax Viking Group · GermanyGerman extinguishers and fixed systems; merged with Viking into Minimax Viking GroupAcquired
  • JockelPresto (Adelis Equity) · GermanyGerman portable and wheeled extinguishers; Presto acquired Jockel Brandschutztechnik in August 2023Acquired
  • NeuruppinGermany
  • OgniochronPoland
  • MOBIAKGreece
  • DesautelFrance
  • EurofeuFrance
  • ANAFItaly
  • PrestoAdelis Equity · SwedenRobotised Swedish extinguisher production plus Nordic and German service networkAcquired
  • ChubbAPi Group · United KingdomExtinguishers and servicing; Carrier sold Chubb Fire & Security to APi GroupAcquired
  • Yamato ProtecJapan
  • HATSUTA SEISAKUSHOJapan
  • Morita MiyataMorita Holdings · JapanJapanese extinguisher maker in the Morita group; superintendents still say MiyataAcquired
  • SFFECO GlobalSaudi Arabia
  • Sea-FireMetalcraft Inc · United StatesMarine extinguishers and engine-room clean-agent units; a division of Baltimore's MetalcraftAcquired

Fixed CO2, clean-agent and aerosol systems

20
Bristol Fire EngineeringBristol Fire EngineeringUnited Arab Emirates
NAFFCONAFFCOUnited Arab Emirates
  • Kidde Fire SystemsPacific Avenue Capital Partners · United StatesMarine CO2 and clean agent; the business was sold out of Chapter 11 in 2024Acquired
  • FenwalPacific Avenue Capital Partners · United StatesDetection and suppression controls; trades with Kidde Fire Systems as KiddeFenwalAcquired
  • ChemetronPacific Avenue Capital Partners · United StatesLegacy marine CO2 and clean agent; chemetron.com now redirects into KiddeFenwalAcquired
  • UnitorWilhelmsen Ships Service · NorwayMarine CO2 batteries, clean-agent and local application extinguishing systemsAcquired
  • AnsulJohnson Controls · United StatesINERGEN inert gas and clean-agent suppression for machinery spacesAcquired
  • MinimaxMinimax Viking Group · GermanyCO2, argon and inert-gas systems for machinery and cargo spacesAcquired
  • Total WaltherJohnson Controls · GermanyHistoric CO2 installations still aboard; entity merged into Johnson Controls Deutschland May 2024Ceased
  • SiemensGermany
  • KoatsuJapan
  • Nohmi BosaiSECOM · JapanTokyo-listed fire-protection maker; gaseous suppression, foam and alarms; SECOM holds the majorityAcquired
  • NKSouth Korea
  • FikeUnited States
  • Rotarex FiretecLuxembourg
  • GielleItaly
  • SIEXSpain
  • WormaldJohnson Controls · AustraliaAustralian fire-protection brand carried inside Johnson Controls' marine and navy portfolioAcquired
  • Fireboy-XintexUnited States
  • FireawayUnited States

Foam systems and concentrate

13
NAFFCONAFFCOUnited Arab Emirates
  • FomtecSweden
  • SOLBERGPerimeter Solutions · NorwayRE-HEALING fluorine-free concentrates; Norwegian plant now inside Perimeter SolutionsAcquired
  • AUXQUIMIAPerimeter Solutions · SpainSpanish foam concentrate maker, high-expansion included; a Perimeter Solutions brandAcquired
  • Angus FireAngus International Safety Group · United KingdomFoam concentrates, hose and monitors; sister company to National FoamAcquired
  • National FoamAngus International Safety Group · United StatesUS foam concentrates and deck systems; same group as Angus FireAcquired
  • Dr. SthamerGermany
  • BIOEXFrance
  • SKUMJohnson Controls · SwedenSwedish deck-foam and monitor brand carried by Johnson ControlsAcquired
  • ChemguardJohnson Controls · United StatesUS foam concentrates and proportioning hardware inside Johnson ControlsAcquired
  • SABO FoamItaly
  • HATSUTA SEISAKUSHOJapan
  • UnitorWilhelmsen Ships Service · NorwayDeck foam concentrate, proportioners and shipboard foam system sparesAcquired

Water mist, sprinkler and deluge

14
  • MarioffInflexion · FinlandHI-FOG high-pressure water mist; sold by Spectrum to Inflexion in 2026Acquired
  • SiemensGermany
  • SEM-SAFESiemens · DenmarkFormerly Danfoss Semco then Danfoss Fire Safety; a separate Siemens entity, SEM-SAFE Fire Safety A/S, since December 2024Renamed
  • FOGTECGermany
  • Ultra FogSweden
  • VID Fire-KillDenmark
  • AquasysAustria
  • TycoJohnson Controls · United StatesAquaMist water mist plus marine sprinkler and deluge under Johnson ControlsAcquired
  • VikingMinimax Viking Group · United StatesSprinkler and deluge maker — not VIKING Life-Saving Equipment, a different companyAcquired
  • Mather + PlattUnited KingdomHistoric sprinkler installations still aboard; the name passed to Wilo, no fire-protection owner remainsWithdrawn
  • GrinnellJohnson Controls · United StatesSprinkler and pipe-fitting brand carried by Johnson ControlsAcquired
  • Reliable Automatic SprinklerUnited States
  • Senju SprinklerJapan
  • DanfossDenmarkHigh-pressure pumps supplied into other makers' mist skids; exited fire safety December 2024Withdrawn

Dry chemical powder systems

11
NAFFCONAFFCOUnited Arab Emirates
Bristol Fire EngineeringBristol Fire EngineeringUnited Arab Emirates
  • UnitorWilhelmsen Ships Service · NorwayDry powder monitors, hose reels and recharge for gas carrier decksAcquired
  • Kidde Fire SystemsPacific Avenue Capital Partners · United StatesDry chemical deck systems for LPG and LNG carriersAcquired
  • AnsulJohnson Controls · United StatesDry chemical systems and agents; long-standing gas carrier installationsAcquired
  • MinimaxMinimax Viking Group · GermanyGerman dry powder skid systems for tanker and gas carrier decksAcquired
  • Total WaltherJohnson Controls · GermanyLegacy gas carrier powder installations; the entity merged into Johnson Controls Deutschland 2024Ceased
  • KoatsuJapan
  • Yamato ProtecJapan
  • AmerexMcWane · United StatesUS dry chemical wheeled units and pre-engineered powder systemsAcquired
  • Buckeye Fire EquipmentUnited States

Fire hoses, nozzles, hydrants

16
NAFFCONAFFCOUnited Arab Emirates
  • Angus FireAngus International Safety Group · United KingdomBritish layflat delivery hose, branchpipes and monitors; Duraline rangeAcquired
  • Akron BrassIDEX · United StatesUS nozzles, monitors and valves; an IDEX fire-and-safety brandAcquired
  • Task Force TipsIDEX · United StatesUS nozzle and monitor maker, now inside IDEXAcquired
  • Elkhart BrassClarience Technologies · United StatesUS nozzles, monitors and hydrant valves; acquired by Clarience Technologies in 2024Acquired
  • POKFrance
  • AWG FittingsIDEX · GermanyGerman Storz couplings, branchpipes and nozzles; a unit of IDEX CorporationAcquired
  • RosenbauerAustria
  • Delta FireUnited Kingdom
  • ZIEGLERCIMC Group · GermanyGerman fire-fighting vehicles, pumps, turrets and hose; Albert Ziegler GmbH, part of CIMCAcquired
  • Mercedes TextilesCanada
  • Teikoku Sen-iJapan
  • Ashimori IndustryJapan
  • Fire Fighting SystemsMadison Industries · NorwayMoss monitors, pumps and external fire-fighting systems; Madison's platform is in the 3M/Bain dealAcquired
  • UnitorWilhelmsen Ships Service · NorwayHoses, nozzles, hydrant valves and international shore connectionsAcquired
  • SFFECO GlobalSaudi Arabia

SCBA and EEBD

11
DrägerDrägerGermany
MSA SafetyMSA SafetyUnited States
  • 3M Scott3M / Bain Capital joint venture · United StatesScott Air-Pak SCBA; moving into the 3M and Bain Capital fire-safety joint ventureAcquired
  • InterspiroOcenco · SwedenSwedish SCBA, Spiroscape EEBD and Divator; owned by Ocenco since 2003Acquired
  • OcencoUnited States
  • Fenzy / SurvivairProtective Industrial Products (Odyssey Investment Partners) · United StatesFormer Honeywell respiratory lines, Fenzy French-built; Honeywell exited PPE May 2025Acquired
  • SpascianiItaly
  • Sundström SafetySweden
  • KokenJapan
  • Shigematsu WorksJapan
  • UnitorWilhelmsen Ships Service · NorwayEEBD sets, spare cylinders and breathing apparatus for shipboard useAcquired

Breathing-air compressors

10
BAUER KOMPRESSORENBAUER KOMPRESSORENGermany
  • L&W CompressorsGermany
  • J.P. Sauer & SohnGermany
  • Aerotecnica ColtriItaly
  • Nardi CompressoriItaly
  • Alkın CompressorsTürkiye
  • CompAirIngersoll Rand · United KingdomHigh-pressure breathing-air compressors; part of the Ingersoll Rand groupAcquired
  • RIX IndustriesUnited States
  • MAKO CompressorsUnited States
  • NuvairUnited States

Fixed fire detection and alarm

19
  • Consilium SafetyAntin Infrastructure Partners · SwedenMarine fire and gas detection; Nordic Capital sold the group to AntinAcquired
  • SalwicoConsilium Safety · SwedenThe marine fire-detection name superintendents still use; now Consilium SafetyRenamed
  • AutronicaMSA Safety · NorwayAutroSafe marine detection; Carrier to Spectrum in 2024, MSA in 2026Acquired
  • HochikiJapan
  • NittanJapan
  • Nohmi BosaiSECOM · JapanTokyo-listed alarm and suppression maker; SECOM holds the voting majorityAcquired
  • Apollo Fire DetectorsHalma · United KingdomBritish detector manufacturer inside Halma; widely used in marine panelsAcquired
  • NotifierHoneywell · United StatesHoneywell's fire-panel and detector brand, common on newbuild installationsAcquired
  • EdwardsKidde Global Solutions · United StatesFire alarm panels and devices; moved with Kidde to Lone StarAcquired
  • AritechKidde Global Solutions · European detection brand inside Kidde Global Solutions; current legal entity's country unconfirmedAcquired
  • GSTKidde Global Solutions · ChinaGulf Security Technology; the group's Chinese fire-detection manufacturerAcquired
  • SimplexJohnson Controls · United StatesFire alarm panels and devices; a Johnson Controls marine and navy brandAcquired
  • Thorn SecurityJohnson Controls · United KingdomBritish fire-detection heritage brand carried by Johnson ControlsAcquired
  • SiemensGermany
  • BoschGermany
  • Wagner GroupGermany
  • XtralisHoneywell · United StatesVESDA aspirating detection, Australian in origin; a Honeywell line since 2016Acquired
  • SecuritonSwitzerland
  • FireyeSpectrum Safety Solutions · United StatesBurner flame safeguards on boilers; sits with Det-Tronics in SpectrumAcquired

Gas, flame and oil-mist detection

19
DrägerDrägerGermany
MSA SafetyMSA SafetyUnited States
RIKEN KEIKIRIKEN KEIKIJapan
  • General MonitorsMSA Safety · United StatesFlame and gas detection brand absorbed by MSA SafetyAcquired
  • New Cosmos ElectricJapan
  • HoneywellUnited States
  • CrowconHalma · United KingdomBritish portable and fixed gas detection; a Halma companyAcquired
  • OldhamTeledyne · FranceFrench fixed gas detection; the old name still on many panelsAcquired
  • SimtronicsTeledyne · NorwayNorwegian open-path gas and flame detection, now a Teledyne brandAcquired
  • Det-TronicsSpectrum Safety Solutions · United StatesFlame and gas detection; carved out of Carrier by Sentinel in 2024Acquired
  • SpectrexEmerson · United StatesOptical flame detectors, now sold through EmersonAcquired
  • MicropackUnited Kingdom
  • Schaller AutomationGermany
  • DASPOSConsilium Safety · DenmarkDanish oil mist detection, now part of Consilium SafetyAcquired
  • GravinerKiddeFenwal (Pacific Avenue Capital Partners) · United KingdomKidde Graviner oil mist detection, MK7 and MK6; supplied by Kidde Fire SystemsAcquired
  • ServomexSpectris · United KingdomOxygen and gas analysers used on inert gas systemsAcquired
  • Industrial ScientificFortive · United StatesUS portable multi-gas detectors and instrument fleet monitoringAcquired
  • Hanla IMSSouth Korea
  • Martek MarineUnited Kingdom

Fire dampers and quick-closing valves

9
  • Halton MarineHalton Group · FinlandA0 and A60 marine fire dampers and galley ventilation equipmentAcquired
  • TROXGermany
  • JevenFinland
  • Heinen & HopmanNetherlands
  • FläktGroupSamsung Electronics · GermanyHerne HVAC group with marine ventilation ranges; Samsung completed the purchase November 2025Acquired
  • Nakakita SeisakushoJapan
  • DamcosEmerson · DenmarkValve remote control actuators for tankers; now an Emerson brandAcquired
  • EconostoNetherlands
  • KLINGERAustria

Main and emergency fire pumps

5
  • IRON PumpDenmark
  • DESMIDenmark
  • Fire Fighting SystemsMadison Industries · NorwayMoss maker of fire pumps and monitors; over 12,000 pumps deliveredAcquired
  • Shinko Ind.Japan
  • GodivaIDEX · United KingdomWarwick portable, vehicle and trailer fire pumps; sold beside sister brand HaleAcquired

Fireman's outfits and firefighter PPE

4
VIKING Life-Saving EquipmentVIKING Life-Saving EquipmentDenmark
  • MSA BristolMSA Safety · United KingdomBristol-sewn structural, USAR and wildland firefighter garments; the former Bristol UniformsAcquired
  • TexportAustria
  • Wolf Safety LampUnited Kingdom

Inert gas and nitrogen generators

3
SurvitecSurvitecUnited Kingdom
  • Maritime ProtectionSurvitec · NorwayKristiansand inert gas, flue gas and nitrogen generators; Survitec's named specialistAcquired
  • Alfa Laval Smit Inert GasAlfa Laval · NetherlandsTanker inert gas and flue gas generators; the former Smit Gas SystemsAcquired

High-pressure cylinders and cylinder valves

3
  • Luxfer Gas CylindersLuxfer Group · United KingdomAluminium and composite SCBA and life-support cylinders; NYSE-listed Luxfer GroupAcquired
  • Faber IndustrieItaly
  • Rotarex FiretecLuxembourg

Passive fire protection and insulation

3
  • ROCKWOOLDenmark
  • PromatEtex Group · BelgiumTisselt passive fire protection boards and sprays, marine among its marketsAcquired
  • Morgan Thermal CeramicsMorgan Advanced Materials · United KingdomFireMaster Marine wraps for A-class decks and bulkheads; DNV and MED certifiedAcquired

Marks are reproduced on their own light ground, unmodified, and are the property of their owners. A mark here identifies equipment this work covers. It does not indicate any endorsement, authorisation or approval of ShipCertify by its owner.

17 of 185 marks on file

Vessel arriving? Send the scope.

Quote and attendance plan by return. Emergency attendance 24/7.