Header band, 2800 x 400 (7:1), WebP o JPG, wala pang 160 KB. HINDI ITO BAGONG LARAWAN: i-crop ang band na ito mula sa gitna ng parehong camera original na pinagmulan ng portrait master ng disiplinang ito, mula sa full-size na file at hindi sa naipasang 1200 x 1800 — tinatanggihan ng uploader ang anumang mas makitid sa 1400 px. Patag na exposure, walang lalagpas sa 60% luminance, walang lens flare, at nasa gitnang ikatlo ang subject upang malinis ang pinapatungan ng teksto sa itaas nito. WALANG NABABASANG PANGALAN NG BARKO, IMO NUMBER O BRANDING NG KLIYENTE.

01

Fire Fighting Appliances (FFA)

Ang Fire Fighting Appliances ay ang inspection, servicing, refilling, pressure testing at certification ng mga fire system ng isang barko — mga extinguisher, fixed CO₂, foam, ang fire main, breathing apparatus at detection. Karamihan ay taunang nagiging due sa ilalim ng mga guideline na iniaatas sundin ng SOLAS II-2 Reg. 14 — A.951(23) §9.1, MSC.1/Circ.1432 §7 at MSC.1/Circ.1318/Rev.1 §5; ang mga extinguisher body, propellant cartridge at CO₂ cylinder ay sinusubok nang hydrostatically sa sampung taon, ang mga steel SCBA cylinder sa lima. Isinasagawa ito ng mga tauhang may kakayahan para sa system. Isinasagawa namin ang scope sa iisang pagdalo sa barko kapag pinapayagan ng haba ng stay, at ibinabalik namin ang mga record, certificate at inventory.

Ang ginagawa namin

Portable at wheeled na extinguisher

  • Taunang inspection ng bawat unit — tag, seal, charge at kalagayan ng body
  • Recharge at refill: mga unit na water, foam, dry powder at CO₂
  • Limang-taong test discharge ng mga portable unit sa loob ng isang drill, at saka recharge at reseal
  • Sampung-taong hydrostatic testing ng mga extinguisher body at propellant cartridge
  • Maaaring magbigay ng mga kapalit na unit at itala ang mga ito sa appliance inventory

Mga fixed extinguishing system

  • Fixed CO₂ — nilalaman ng cylinder na sinusuri sa pamamagitan ng pagtimbang o level indication
  • Sinusubok ang CO₂ distribution pipework, flexible hose, release line at alarm
  • Sampung-taong hydrostatic test ng mga CO₂ cylinder — 10% na sample na tumataas kapag may hindi pumasa, at lahat ng cylinder bago ang ika-20 taong anibersaryo at sa bawat ika-10 taong anibersaryo pagkatapos nito
  • Fixed foam — pagsubok sa proportioner at pagkuha ng sample ng concentrate para sa laboratory analysis
  • Water-mist, sprinkler at deluge — pagsubok bawat section, pagsusuri sa pump at nozzle
  • Fixed dry chemical powder, karaniwan sa mga gas carrier — powder, propellant at pipework, tuwing dalawang taon

Fire main, hose at pump

  • Ang mga fire hose ay pressure tested sa maximum fire main pressure — bawat length sa loob ng limang-taong cycle, bawat isa ay kinikilala sa sarili nitong numero
  • Ang mga nozzle, coupling, hydrant at applicator ay sinusuri, function tested at pinapalitan
  • Maaaring palitan ang mga length na hindi pumasa kapag ang kapalit ay ibinibigay kasama ng trabaho
  • Emergency fire pump — starting arrangement, suction lift at delivery pressure
  • International shore connection — pagkakaroon, kalagayan, gasket, bolts at lokasyon ng stowage

Breathing apparatus at mga outfit

  • SCBA — taunang service, function test, low-pressure warning at demand valve
  • SCBA cylinder — limang-taong hydrostatic test para sa steel; ang iba ay ayon sa Administration
  • Ang output ng breathing-air compressor ay kinukuhanan ng sample at sinusuri laban sa EN 12021
  • EEBD — inspection, kontrol sa expiry, pagpapalit at pagtatapon ng mga expired na unit
  • Firefighter's outfit — sinusuri ang mga suit, helmet, boots, gloves, lifeline at lamp

Detection, closing appliance, dokumento

  • Mga fixed fire detection at alarm loop — functional testing, zone bawat zone
  • Ang mga portable gas detector at explosimeter ay kina-calibrate laban sa certified span gas
  • Fire damper at ventilation closing appliance — sinusubok ang operasyon at ang pagsasara
  • Quick-closing valve — sinusubok ang remote at local na operasyon, at saka ini-reset
  • Ang fire control plan ay sinusuri laban sa mga appliance na talagang nakakabit sa barko
  • Ang inventory ng fire-fighting appliance ay itinutugma, itinatama at muling iniisyu
  • Ang lingguhan, buwanan at quarterly na record ng crew ay tinitiyak laban sa maintenance plan ng Reg. 14

Batayang regulasyon

Ang mga instrument na namamahala sa gawaing ito, sinipi sa paraang isusulat ito ng isang superintendent. Kung ano ang hinihingi ng bawat isa sa shipowner — hindi kung ano ang ibinebenta namin.

SOLAS Ch. II-2Construction — fire protection, fire detection and fire extinction (SOLAS 1974, gaya ng sinusugan)

Ang mga fire protection system, fire-fighting system at appliance ay dapat panatilihing nasa mabuting kalagayan at handa para sa agarang paggamit, at ang isang na-discharge na portable extinguisher ay dapat agad na i-recharge o palitan ng katumbas na unit. Ang maintenance, testing at inspection ay isinasagawa batay sa mga guideline na binuo ng Organization, sa ilalim ng isang maintenance plan na itinatago sa barko (Reg. 14.2).

FSS CodeInternational Code for Fire Safety Systems (IMO Res. MSC.98(73), gaya ng sinusugan)

Itinatakda nito ang specification na dapat matugunan ng bawat fire safety system — mga extinguisher, fixed gas, foam, water-spraying at sprinkler system, fire detection, breathing apparatus. Dapat manatili ang kagamitan sa specification na pinagbatayan ng pag-approve dito.

MSC.1/Circ.1432 gaya ng sinusugan ng MSC.1/Circ.1516Revised guidelines for the maintenance and inspection of fire protection systems and appliances, gaya ng sinusugan ng MSC.1/Circ.1516 (mga aytem para sa sprinkler system at kalidad ng tubig)

Nagtatakda ng pinakamababang inirerekomendang antas ng maintenance at inspection sa likod ng plano ng SOLAS II-2/14.2.2.1: mga aytem mula lingguhan hanggang tuwing sampung taon para sa fire main, hose, fixed gas, foam, water-mist, powder, detection at breathing apparatus. Hindi nito saklaw ang portable extinguisher o ang fixed CO₂.

IMO Res. A.951(23)Improved Guidelines for Marine Portable Fire Extinguishers

Mga guideline para sa portable extinguisher: service sa mga agwat na hindi hihigit sa isang taon; test discharge ng isang extinguisher sa bawat uri na ginawa sa parehong taon tuwing limang taon, sa loob ng isang drill; hydraulic testing ng mga extinguisher at propellant cartridge tuwing sampung taon.

MSC.1/Circ.1318/Rev.1Revised guidelines for the maintenance and inspections of fixed carbon dioxide fire-extinguishing systems (pumapalit sa MSC.1/Circ.1318)

Ang pinakamababang inirerekomendang maintenance para sa mga fixed CO₂ system sa ilalim ng SOLAS II-2/14.2.1.2: visual check tuwing 30 araw (§4), taunang inspection (§5), nilalaman ng cylinder na tinitiyak laban sa 90% na charge threshold tuwing dalawang taon o sa survey (§6.1.1), internal inspection ng lahat ng control valve tuwing limang taon (§7), at hydrostatic testing ng mga high-pressure cylinder sa mga agwat na hindi hihigit sa sampung taon — 10% na sample sa 10-taong inspection, ngunit lahat ng cylinder bago ang ika-20 taong anibersaryo at sa bawat ika-10 taong anibersaryo pagkatapos nito (§6.1.2).

SOLAS Reg. I/8 · SOLAS Reg. I/7Surveys of life-saving appliances and other equipment of cargo ships (I/8); surveys of passenger ships (I/7)

Mga cargo ship na 500 gross tonnage pataas: annual survey sa loob ng tatlong buwan mula sa petsa ng anibersaryo, isang periodical survey sa ikalawa o ikatlong anibersaryo, at renewal sa loob ng limang taon (I/8). Ang mga passenger ship ay sumasailalim sa renewal survey isang beses tuwing 12 buwan (I/7); ang Passenger Ship Safety Certificate mismo ay iniisyu nang hindi hihigit sa 12 buwan (I/14).

Mga Interval

Kung ano ang due, gaano kadalas, at kung aling instrument ang nagtatakda ng panahon. Kapag ang isang interval ay nagmumula sa manufacturer o sa class sa halip na sa isang IMO instrument, nakasaad iyon sa talahanayan.

Mga interval ng survey at service para sa Fire Fighting Appliances (FFA)
ItemIntervalItinakda ngTala
Portable at wheeled na fire extinguisher — inspectionTaunanIMO Res. A.951(23), §9.1 (portable) · MSC.1/Circ.1432, §7.12 (wheeled)safety clip, pressure indicator, timbang laban sa full charge, hose at nozzle; ang mga powder unit ay binabaligtad
Fire extinguisher — limang-taong serviceTuwing 5 taonIMO Res. A.951(23), §9.1.1 (portable) · MSC.1/Circ.1432, §9.6 (wheeled)isa sa bawat uri na ginawa sa taong iyon: ang mga portable ay isinasailalim sa test discharge sa isang drill, ang mga wheeled ay sinusuri
Extinguisher body at propellant cartridge — hydrostatic testTuwing 10 taonIMO Res. A.951(23), §9.1.2 (portable) · MSC.1/Circ.1432, §10.5 (wheeled)ayon sa kinikilalang pamantayan o sa tagubilin ng maker; ang petsa ay nakatatak sa body; ang mga hindi pumasa ay pinapalitan
Fixed CO₂ system — taunang inspectionTaunanMSC.1/Circ.1318/Rev.1, §5mga boundary opening, container, piping, nozzle, manifold, flexible hose, entrance door, warning sign
Fixed CO₂ cylinder — nilalaman na tinitiyak sa pamamagitan ng pagtimbangTuwing 2 taon ±3 buwan (passenger ship); sa bawat intermediate, periodical o renewal survey (cargo ship)MSC.1/Circ.1318/Rev.1, §6.1.1ang mga cylinder na wala pang 90% ng nominal charge ay nire-refill
Fixed CO₂ cylinder — hydrostatic test, pagpapalit ng hoseTuwing 10 taonMSC.1/Circ.1318/Rev.1, §6.1.2hindi bababa sa 10% ang sinusuri sa loob at hydrostatically tested sa 10-taong inspection, 50% kung may isang hindi pumasa at lahat kung may iba pang cylinder na hindi pumasa; at lahat ng cylinder bago ang ika-20 taong anibersaryo at sa bawat ika-10 taong anibersaryo pagkatapos nito
Fixed foam, water-mist at sprinkler system — testTaunan; ang mga control test ng foam concentrate ay hindi hihigit sa 3 taon matapos ang supply at taun-taon pagkatapos nito — ang mga protein-based at alcohol-resistant na concentrate ay bago ang delivery at taunan mula sa simulaMSC.1/Circ.1432, §7.4 at §7.5 · MSC.1/Circ.1312, §5 (concentrate)ang concentrate ay kinukuhanan ng sample sa barko at sinusuri sa lupa; ang mga proportioner ay sinusubok sa +30/-10% sa limang taon (§9.2.4)
Fire main, pump, hydrant, nozzle at hoseTaunan; bawat hose length ay pressure tested sa loob ng 5 taonMSC.1/Circ.1432, §7.1ang hose sample ay sinusubok sa maximum fire main pressure; sinusuri ang emergency fire pump at ang shore connection
Fixed fire detection at alarm — functional testTaunanMSC.1/Circ.1432, §7.2ang gas detection ay walang interval dito — ang schedule ng maker ng detector at ang flag o class ang umiiral
Breathing apparatus, kalidad ng breathing-air at EEBDTaunanMSC.1/Circ.1432, §7.8 at §7.8.1sinusuri ang mga face mask at demand valve, ang recharging air ay sinusuri laban sa EN 12021; ang mga gauge ay lingguhan (§4.5)
SCBA cylinder — hydrostatic testTuwing 5 taon (steel na cylinder)MSC.1/Circ.1432, §9.4aluminium at composite ayon sa kasiyahan ng Administration; ang retest date ay nakatatak sa cylinder
Fire damper at ventilation closing appliance — remote operation testTaunanMSC.1/Circ.1432, §7.6.1 (fire damper, remote operation) · §7.6.3 (mga ventilation control na magkaugnay sa fire-protection system)bawat damper ay pinapaandar mula sa remote position nito at ini-reset; ang local damper operation ay tuwing quarter (§6.3). Ang firefighter's outfit ay walang taunang interval sa MSC.1/Circ.1432 — ang §5.5 ay buwanang pagsusuri na kumpleto at serviceable ang outfit locker — at ang engine-room quick-closing valve ay nasa labas ng saklaw ng circular; pareho itong isinasagawa ayon sa schedule ng maker at sa hinihingi ng flag o class
Safety equipment survey — cargo at passenger shipCargo: taunan ±3 buwan, periodical sa ika-2 o ika-3 anibersaryo, renewal ≤5 taon · Passenger: tuwing 12 buwanSOLAS Reg. I/8 (cargo ship, 500 GT pataas) · SOLAS Reg. I/7 (passenger ship)ang survey mismo ay isinasagawa ng flag Administration o ng Recognised Organisation nito — ang hanay na ito ang deadline na pinagbabatayan ng pagpaplano ng service work, hindi isang survey na isinasagawa namin; ang periodical survey ang pumapalit sa annual survey para sa taong iyon
Na-discharge na extinguisher; anumang system na hindi agad handaAgad-agadSOLAS II-2/14.2 — operational readinessni-recharge o pinalitan ng katumbas na unit; may alternatibong proteksiyon habang isinasagawa ang trabaho

Ang matatanggap ninyo

  • FFA attendance report at isang service certificate para sa bawat system na na-service — nilagdaan ng attending technician at kinontrasignahan sa barko, na nagsasaad ng barko, IMO number, port, petsa at ang instrument na pinagbatayan ng gawain
  • Service record at inspection tag ng fire extinguisher para sa bawat unit, at, para sa bawat pressure vessel na ibinaba para sa hydrostatic test, ang sariling certificate ng test facility na ipinapasa sa inyo — na nagsasaad ng pasilidad na nagsagawa at nagtatak ng test, ang petsa ng test at ang nakatatak na retest date
  • Test report para sa fixed CO₂, foam, water-mist, sprinkler at fixed detection — cylinder bawat cylinder, section bawat section at zone bawat zone, na may naitalang readings sa halip na pass mark lamang, kasama ang laboratory analysis ng foam concentrate laban sa mga periodical control test
  • Pressure test record ng fire hose at hydrant — bawat length ay kinikilala sa sarili nitong numero, ang test pressure na ipinataw, pass o fail, at ang mga length na pinalitan
  • SCBA service record sa bawat set, cylinder retest certificate, breathing-air analysis laban sa EN 12021, at mga record ng EEBD at ng firefighter's outfit unit bawat unit
  • Calibration certificate para sa bawat portable gas detector at explosimeter, na nagsasaad ng span gas na ginamit, ang sariling certificate reference ng gas na iyon at ang petsa ng calibration — isang record ng pagsusuring isinagawa laban sa gas na iyon. Wala kaming inilalathalang accreditation scope para sa gawaing ito, kaya kung hinihingi ng inyong flag, class o charterer ang calibration sa ilalim ng isang accredited scope, sabihin po ninyo ito sa inyong pagtatanong at sasabihin namin sa inyo nang nakasulat kung madodokumento namin ito
  • Inventory ng fire-fighting appliance na itinugma sa fire control plan, at ang listahan ng defect at rekomendasyon na iniaabot sa barko bago kami umalis, kasama ang quotation para sa anumang kapalit na parts
  • Every record dated and carrying its next due date, in a form that files straight into the SOLAS II-2 Reg. 14 maintenance plan — the full pack as signed PDFs within five working days of the team leaving the vessel, and within 24 hours where the vessel sails before then or a certificate expires before then, provided you tell us at the order that the date is tight. A certificate is issued only for what passed: where an item fails, the defect list goes out on that same clock and the certificate for that item follows the re-test. Cylinders landed for hydrostatic test run on their own clock — that facility's certificate reaches you when the test house issues it. Copies and reissues come from docs@shipcertify.com.

Saan

Pinaplano ang pagdalo sa barko mula sa pinakamalapit sa 6 service base tungo sa alinman sa 299 port na nasa nailathalang index, sa anumang oras ng araw o gabi. Kung wala sa listahan ang inyong port, magtanong po — ang index ay kung ano ang inilalathala namin, hindi ang hangganan ng aming pag-mobilize.

Buksan ang port index

Mga tanong na talagang itinatanong sa amin

Approved ba kayo para sa aming flag?

Wala kaming inilalathalang authorisation scope sa site na ito, at walang approval certificate — huwag pong basahin ang anuman dito bilang pag-aangkin, sa alinmang panig. Sabihin po ninyo sa amin ang flag, ang barko at ang scope. Anumang dokumentasyong nauukol sa gawaing iyon ay ibinibigay nang nakasulat kasama ng quotation — ang nagkakaloob na entidad, ang scope, ang reference, at ang register kung saan ninyo ito masusuri. Kung hindi namin madodokumento ang scope para sa inyong flag, sasabihin namin ito bago pa kayo mag-award.

Kaya ba ninyong matapos ang lahat sa loob ng 18-oras na port stay?

Send ETA, ETD, berth and scope. We attend from the nearest of six bases — Istanbul, Izmir, Iskenderun, Varna, Constanta, London — and say what fits the window before you commit. Where the stay is short we split by what the certificate needs first. Time on board for a full FFA scope — every extinguisher, the fire main, hoses and nozzles, detection, SCBA sets, fixed systems and dampers — with two technicians, boarding to landing: a coaster, tug or general cargo ship under about 10,000 GT, 8 to 12 hours; a bulk carrier, tanker or container ship of about 10,000 to 50,000 GT, 14 to 20 hours; above 50,000 GT, 20 to 30 hours, which we run as two shifts or with a third technician to bring it inside one stay. A passenger ship or ro-pax is quoted on the extinguisher and detection-zone count rather than banded. What moves those hours is the number of extinguishers and detection zones, not the deadweight — and cargo work over a protected space, which holds the fixed-system tests until it stops. Cylinders landed for hydrostatic test do not come back inside the same stay. Vessel alongside: 24/7 hotline +90 532 657 48 78.

Tatanggapin ba ng class at ng Port State Control ang inyong certificate?

Dalawang bagay ang batayan ng pagtanggap: na ang gumagawa ng trabaho ay may hawak na authorisation na hinihingi ng inyong surveyor, at na ipinapakita ng record kung ano ang aktuwal na ginawa. Wala sa dalawang ito ang magagarantiya namin sa ngalan ng isang surveyor. Wala kaming inilalathalang authorisation scope dito. Sabihin po ninyo ang flag, class society at scope; anumang dokumentasyong nauukol ay ipinapadala kasama ng quotation, upang suriin ninyo sa pampublikong register ng nagkaloob nito bago kayo mag-award — at kung hindi namin madodokumento ang scope na hinihingi ng inyong surveyor, sasabihin namin ito bago kayo mag-award sa halip na hayaan kayong ipagpalagay ito. Taglay ng report ang instrument, interval, resulta bawat unit at ang mga defect.

Ano ang mangyayari kung may makita kayong hindi pumasa?

It goes on the defect list with the reason and the instrument it fails against, and you are told on board, not in an email a week later. Parts and consumables required during the service can be supplied with the job, quoted and invoiced against the same attendance. What can actually be fitted before we leave, and what has to be ordered, depends on the item and the port — we tell you which it is on board rather than leaving you to find a second vendor. Which makes and types can be put on board is answered against your equipment list rather than from a stock list published here, because a stock position printed on a website is stale the week after it is written: send the appliance inventory with the scope sheet — make, type, capacity and the date stamped on each unit — and the quotation states, item by item, what can be on board for that attendance, which base it comes from, and what has to be ordered, with the documentation each item carries. Spares: spares@shipcertify.com.

Aling mga cylinder ang ipinapadala para sa hydrostatic test, at umaalis ba ang mga ito sa barko?

Portable extinguisher bodies and propellant cartridges at ten years. On a fixed CO₂ bank, at least 10% at the ten-year inspection, rising to 50% then all if any fail — and under MSC.1/Circ.1318/Rev.1 every cylinder goes for test before the 20-year anniversary and at each 10-year anniversary after that. Steel SCBA cylinders run on five years (MSC.1/Circ.1432 §9.4); aluminium and composite to the satisfaction of the Administration. Hydrostatic testing is a workshop operation — cylinders are landed and returned. They go to a facility competent to perform and stamp the test; the quotation names that facility before the work starts, and its own certificate is passed through to you unaltered rather than restated on ours. Plan on 5 to 10 working days from landing to return alongside at a port served from one of our own bases — Istanbul, Izmir, Iskenderun, Varna, Constanta, London — and 10 to 15 working days where the cylinders move through the partner network from a port without a base, or where export and re-import formalities apply to a pressure vessel. The quotation gives the figure for your named port. A fixed CO₂ bank is the long pole: cylinders emptied for test have to be refilled, weighed and refitted before the system is back in service. Where the vessel sails first, tell us at the order which port to return them to and they are held and delivered on a later call.

Malapit nang mag-due ang survey para sa Safety Equipment Certificate. Ano ang kailangan ninyo mula sa amin?

Ang huling service record ng bawat system, ang fire control plan, ang appliance inventory, at ang petsa at port ng survey. Isinasagawa namin ang scope batay sa kung ano ang bubuksan ng surveyor — mga expiry date, hydrostatic test stamp, petsa ng foam analysis, petsa ng SCBA cylinder — at ibinibigay namin sa inyo ang defect list bago pa makasulat ng isa ang surveyor.

Mga make at type na sineserbisyuhan namin

Ang equipment na talagang matatagpuan sa mga barko, naka-index ayon sa kategorya, kasama ang corporate history na kailangan ng isang superintendent — may plate pa ring nakasulat na Norsafe, Schat-Harding, Germanischer Lloyd. Ito ang saklaw ng gawain. Hindi ito listahan ng mga approval: ipinagkakaloob ang maker authorisation sa bawat make at bawat type, at ang sa amin ay ibinibigay nang nakasulat kasama ng quotation.

185 sa 185 na make

Portable at wheeled extinguishers

25
GLORIAGLORIAGermany
LALIZASLALIZASGreece
DafoDafoSweden
NAFFCONAFFCOUnited Arab Emirates
  • UnitorWilhelmsen Ships Service · NorwayShipboard extinguishers, CO2, foam at powder; ang Unitor ang marine brand ng WilhelmsenNabili
  • KiddeKidde Global Solutions · Estados UnidosMga extinguisher at marine system; umalis sa Carrier patungong Lone Star Funds noong Disyembre 2024Nabili
  • BadgerKidde Global Solutions · Estados UnidosUS na brand ng extinguisher, nasa loob na ngayon ng Kidde Global Solutions katabi ng Kidde at EdwardsNabili
  • AmerexMcWane · Estados UnidosMga portable at wheeled extinguisher mula US; pag-aari ng grupong McWaneNabili
  • AnsulJohnson Controls · Estados UnidosMga extinguisher, dry chemical at foam; brand ng Tyco na dinala sa Johnson ControlsNabili
  • Buckeye Fire EquipmentEstados Unidos
  • MinimaxMinimax Viking Group · GermanyGerman na extinguishers at fixed systems; nagsanib sa Viking bilang Minimax Viking GroupNabili
  • JockelPresto (Adelis Equity) · GermanyMga Alemang portable at wheeled extinguisher; binili ng Presto ang Jockel Brandschutztechnik noong Agosto 2023Nabili
  • NeuruppinGermany
  • OgniochronPoland
  • MOBIAKGreece
  • DesautelFrance
  • EurofeuFrance
  • ANAFItaly
  • PrestoAdelis Equity · SwedenRobotisadong produksyon ng extinguisher sa Sweden kasama ang service network sa Nordic at AlemanyaNabili
  • ChubbAPi Group · United KingdomMga extinguisher at servicing; ibinenta ng Carrier ang Chubb Fire & Security sa APi GroupNabili
  • Yamato ProtecJapan
  • HATSUTA SEISAKUSHOJapan
  • Morita MiyataMorita Holdings · JapanJapanese na gumagawa ng extinguisher sa grupong Morita; Miyata pa rin ang tawag ng mga superintendentNabili
  • SFFECO GlobalSaudi Arabia
  • Sea-FireMetalcraft Inc · Estados UnidosMarine extinguishers at engine-room clean-agent units; isang dibisyon ng Metalcraft ng BaltimoreNabili

Fixed CO2, clean-agent at aerosol systems

20
Bristol Fire EngineeringBristol Fire EngineeringUnited Arab Emirates
NAFFCONAFFCOUnited Arab Emirates
  • Kidde Fire SystemsPacific Avenue Capital Partners · Estados UnidosMarine CO2 at clean agent; ipinagbili ang negosyo mula sa Chapter 11 noong 2024Nabili
  • FenwalPacific Avenue Capital Partners · Estados UnidosMga detection at suppression control; nangangalakal kasama ang Kidde Fire Systems bilang KiddeFenwalNabili
  • ChemetronPacific Avenue Capital Partners · Estados UnidosLegacy na marine CO2 at clean agent; ang chemetron.com ay nagre-redirect na ngayon patungo sa KiddeFenwalNabili
  • UnitorWilhelmsen Ships Service · NorwayMarine CO2 batteries, clean-agent at local application extinguishing systemsNabili
  • AnsulJohnson Controls · Estados UnidosINERGEN inert gas at clean-agent suppression para sa machinery spacesNabili
  • MinimaxMinimax Viking Group · GermanyCO2, argon at inert-gas systems para sa machinery at cargo spacesNabili
  • Total WaltherJohnson Controls · GermanyMakasaysayang CO2 installations na nasa barko pa rin; isinanib ang entity sa Johnson Controls Deutschland Mayo 2024Itinigil
  • SiemensGermany
  • KoatsuJapan
  • Nohmi BosaiSECOM · JapanGumagawa ng fire protection na nakalista sa Tokyo; gaseous suppression, foam at mga alarm; hawak ng SECOM ang mayoryaNabili
  • NKTimog Korea
  • FikeEstados Unidos
  • Rotarex FiretecLuxembourg
  • GielleItaly
  • SIEXSpain
  • WormaldJohnson Controls · AustraliaAustralyanong fire-protection brand na dala sa loob ng marine at navy portfolio ng Johnson ControlsNabili
  • Fireboy-XintexEstados Unidos
  • FireawayEstados Unidos

Foam systems at concentrate

13
NAFFCONAFFCOUnited Arab Emirates
  • FomtecSweden
  • SOLBERGPerimeter Solutions · NorwayMga RE-HEALING fluorine-free concentrate; ang planta sa Norway ay nasa loob na ng Perimeter SolutionsNabili
  • AUXQUIMIAPerimeter Solutions · SpainSpanish na gumagawa ng foam concentrate, kasama ang high-expansion; isang brand ng Perimeter SolutionsNabili
  • Angus FireAngus International Safety Group · United KingdomFoam concentrates, hose at monitors; kapatid na kompanya ng National FoamNabili
  • National FoamAngus International Safety Group · Estados UnidosUS foam concentrates at deck systems; iisang grupo kasama ng Angus FireNabili
  • Dr. SthamerGermany
  • BIOEXFrance
  • SKUMJohnson Controls · SwedenSwedish na brand ng deck-foam at monitor na dala ng Johnson ControlsNabili
  • ChemguardJohnson Controls · Estados UnidosUS foam concentrates at proportioning hardware sa loob ng Johnson ControlsNabili
  • SABO FoamItaly
  • HATSUTA SEISAKUSHOJapan
  • UnitorWilhelmsen Ships Service · NorwayDeck foam concentrate, proportioners at mga spare para sa shipboard foam systemNabili

Water mist, sprinkler at deluge

14
  • MarioffInflexion · FinlandHI-FOG high-pressure water mist; ipinagbili ng Spectrum sa Inflexion noong 2026Nabili
  • SiemensGermany
  • SEM-SAFESiemens · DenmarkDating Danfoss Semco at pagkatapos ay Danfoss Fire Safety; isang hiwalay na Siemens entity, SEM-SAFE Fire Safety A/S, mula Disyembre 2024Pinalitan ng pangalan
  • FOGTECGermany
  • Ultra FogSweden
  • VID Fire-KillDenmark
  • AquasysAustria
  • TycoJohnson Controls · Estados UnidosAquaMist water mist kasama ang marine sprinkler at deluge sa ilalim ng Johnson ControlsNabili
  • VikingMinimax Viking Group · Estados UnidosGumagawa ng sprinkler at deluge — hindi ito ang VIKING Life-Saving Equipment, ibang kompanya iyonNabili
  • Mather + PlattUnited KingdomMay mga lumang sprinkler installation pa ring nakasakay; napunta ang pangalan sa Wilo, wala nang natitirang may-ari sa fire protectionBinawi
  • GrinnellJohnson Controls · Estados UnidosBrand ng sprinkler at pipe-fitting na dala ng Johnson ControlsNabili
  • Reliable Automatic SprinklerEstados Unidos
  • Senju SprinklerJapan
  • DanfossDenmarkMga high-pressure pump na sinusuplay sa mist skids ng ibang maker; umalis sa fire safety noong Disyembre 2024Binawi

Dry chemical powder systems

11
NAFFCONAFFCOUnited Arab Emirates
Bristol Fire EngineeringBristol Fire EngineeringUnited Arab Emirates
  • UnitorWilhelmsen Ships Service · NorwayDry powder monitors, hose reels at recharge para sa mga deck ng gas carrierNabili
  • Kidde Fire SystemsPacific Avenue Capital Partners · Estados UnidosDry chemical deck systems para sa mga LPG at LNG carrierNabili
  • AnsulJohnson Controls · Estados UnidosMga dry chemical system at agent; matagal nang mga installation sa mga gas carrierNabili
  • MinimaxMinimax Viking Group · GermanyMga Alemang dry powder skid system para sa mga kubyerta ng tanker at gas carrierNabili
  • Total WaltherJohnson Controls · GermanyMga legacy na powder installation sa gas carrier; isinanib ang entity sa Johnson Controls Deutschland 2024Itinigil
  • KoatsuJapan
  • Yamato ProtecJapan
  • AmerexMcWane · Estados UnidosUS dry chemical wheeled units at pre-engineered powder systemsNabili
  • Buckeye Fire EquipmentEstados Unidos

Fire hoses, nozzles, hydrants

16
NAFFCONAFFCOUnited Arab Emirates
  • Angus FireAngus International Safety Group · United KingdomBritish layflat delivery hose, branchpipes at monitors; Duraline rangeNabili
  • Akron BrassIDEX · Estados UnidosUS nozzles, monitors at valves; isang fire-and-safety brand ng IDEXNabili
  • Task Force TipsIDEX · Estados UnidosUS na gumagawa ng nozzle at monitor, nasa loob na ngayon ng IDEXNabili
  • Elkhart BrassClarience Technologies · Estados UnidosMga nozzle, monitor at hydrant valve mula US; binili ng Clarience Technologies noong 2024Nabili
  • POKFrance
  • AWG FittingsIDEX · GermanyMga Alemang Storz coupling, branchpipe at nozzle; isang yunit ng IDEX CorporationNabili
  • RosenbauerAustria
  • Delta FireUnited Kingdom
  • ZIEGLERCIMC Group · GermanyMga Alemang fire-fighting vehicle, pump, turret at hose; Albert Ziegler GmbH, bahagi ng CIMCNabili
  • Mercedes TextilesCanada
  • Teikoku Sen-iJapan
  • Ashimori IndustryJapan
  • Fire Fighting SystemsMadison Industries · NorwayMoss monitors, pumps at external fire-fighting systems; ang platform ng Madison ay nasa 3M/Bain dealNabili
  • UnitorWilhelmsen Ships Service · NorwayMga hose, nozzle, hydrant valve at international shore connectionNabili
  • SFFECO GlobalSaudi Arabia

SCBA at EEBD

11
DrägerDrägerGermany
MSA SafetyMSA SafetyEstados Unidos
  • 3M Scott3M / Bain Capital joint venture · Estados UnidosScott Air-Pak SCBA; lumilipat sa fire-safety joint venture ng 3M at Bain CapitalNabili
  • InterspiroOcenco · SwedenSwedish na SCBA, Spiroscape EEBD at Divator; pagmamay-ari ng Ocenco mula 2003Nabili
  • OcencoEstados Unidos
  • Fenzy / SurvivairProtective Industrial Products (Odyssey Investment Partners) · Estados UnidosDating respiratory lines ng Honeywell, Fenzy na gawang Pranses; umalis ang Honeywell sa PPE Mayo 2025Nabili
  • SpascianiItaly
  • Sundström SafetySweden
  • KokenJapan
  • Shigematsu WorksJapan
  • UnitorWilhelmsen Ships Service · NorwayMga EEBD set, ekstrang silindro at breathing apparatus para sa gamit sa barkoNabili

Breathing-air compressors

10
BAUER KOMPRESSORENBAUER KOMPRESSORENGermany
  • L&W CompressorsGermany
  • J.P. Sauer & SohnGermany
  • Aerotecnica ColtriItaly
  • Nardi CompressoriItaly
  • Alkın CompressorsTürkiye
  • CompAirIngersoll Rand · United KingdomHigh-pressure breathing-air compressors; bahagi ng grupong Ingersoll RandNabili
  • RIX IndustriesEstados Unidos
  • MAKO CompressorsEstados Unidos
  • NuvairEstados Unidos

Fixed fire detection at alarm

19
  • Consilium SafetyAntin Infrastructure Partners · SwedenMarine fire at gas detection; ipinagbili ng Nordic Capital ang grupo sa AntinNabili
  • SalwicoConsilium Safety · SwedenAng pangalan sa marine fire detection na ginagamit pa rin ng mga superintendent; ngayon ay Consilium SafetyPinalitan ng pangalan
  • AutronicaMSA Safety · NorwayAutroSafe marine detection; Carrier patungong Spectrum noong 2024, MSA noong 2026Nabili
  • HochikiJapan
  • NittanJapan
  • Nohmi BosaiSECOM · JapanGumagawa ng alarm at suppression na nakalista sa Tokyo; hawak ng SECOM ang mayorya ng botoNabili
  • Apollo Fire DetectorsHalma · United KingdomBritish na tagagawa ng detector sa loob ng Halma; malawakang ginagamit sa mga marine panelNabili
  • NotifierHoneywell · Estados UnidosAng fire-panel at detector brand ng Honeywell, karaniwan sa mga newbuild installationNabili
  • EdwardsKidde Global Solutions · Estados UnidosMga fire alarm panel at device; lumipat kasama ng Kidde patungo sa Lone StarNabili
  • AritechKidde Global Solutions · Europeong detection brand sa loob ng Kidde Global Solutions; hindi pa nakukumpirma ang bansa ng kasalukuyang legal entityNabili
  • GSTKidde Global Solutions · ChinaGulf Security Technology; ang Chinese na tagagawa ng fire detection ng grupoNabili
  • SimplexJohnson Controls · Estados UnidosFire alarm panels at devices; isang marine at navy brand ng Johnson ControlsNabili
  • Thorn SecurityJohnson Controls · United KingdomBritanikong heritage brand sa fire detection na dala ng Johnson ControlsNabili
  • SiemensGermany
  • BoschGermany
  • Wagner GroupGermany
  • XtralisHoneywell · Estados UnidosVESDA aspirating detection, Australyano ang pinagmulan; linya ng Honeywell mula noong 2016Nabili
  • SecuritonSwitzerland
  • FireyeSpectrum Safety Solutions · Estados UnidosMga burner flame safeguard sa mga boiler; kasama ng Det-Tronics sa SpectrumNabili

Gas, flame at oil-mist detection

19
DrägerDrägerGermany
MSA SafetyMSA SafetyEstados Unidos
RIKEN KEIKIRIKEN KEIKIJapan
  • General MonitorsMSA Safety · Estados UnidosBrand ng flame at gas detection na isinanib sa MSA SafetyNabili
  • New Cosmos ElectricJapan
  • HoneywellEstados Unidos
  • CrowconHalma · United KingdomBritanikong portable at fixed gas detection; isang kompanya ng HalmaNabili
  • OldhamTeledyne · FrancePranses na fixed gas detection; nasa maraming panel pa rin ang lumang pangalanNabili
  • SimtronicsTeledyne · NorwayNorwegong open-path gas at flame detection, isa nang brand ng TeledyneNabili
  • Det-TronicsSpectrum Safety Solutions · Estados UnidosFlame at gas detection; inihiwalay mula sa Carrier ng Sentinel noong 2024Nabili
  • SpectrexEmerson · Estados UnidosOptical flame detectors, ibinebenta na ngayon sa pamamagitan ng EmersonNabili
  • MicropackUnited Kingdom
  • Schaller AutomationGermany
  • DASPOSConsilium Safety · DenmarkDanish na oil mist detection, ngayon ay bahagi ng Consilium SafetyNabili
  • GravinerKiddeFenwal (Pacific Avenue Capital Partners) · United KingdomKidde Graviner oil mist detection, MK7 at MK6; sinusuplay ng Kidde Fire SystemsNabili
  • ServomexSpectris · United KingdomMga oxygen at gas analyser na ginagamit sa mga inert gas systemNabili
  • Industrial ScientificFortive · Estados UnidosMga portable multi-gas detector mula US at instrument fleet monitoringNabili
  • Hanla IMSTimog Korea
  • Martek MarineUnited Kingdom

Fire dampers at quick-closing valves

9
  • Halton MarineHalton Group · FinlandMga A0 at A60 marine fire damper at kagamitan sa galley ventilationNabili
  • TROXGermany
  • JevenFinland
  • Heinen & HopmanNetherlands
  • FläktGroupSamsung Electronics · GermanyGrupong HVAC sa Herne na may mga marine ventilation range; kinumpleto ng Samsung ang pagbili noong Nobyembre 2025Nabili
  • Nakakita SeisakushoJapan
  • DamcosEmerson · DenmarkValve remote control actuators para sa mga tanker; isa nang brand ng EmersonNabili
  • EconostoNetherlands
  • KLINGERAustria

Main at emergency fire pumps

5
  • IRON PumpDenmark
  • DESMIDenmark
  • Fire Fighting SystemsMadison Industries · NorwayGumagawa ng fire pump at monitor mula sa Moss; mahigit 12,000 pump ang naihatidNabili
  • Shinko Ind.Japan
  • GodivaIDEX · United KingdomWarwick portable, vehicle at trailer fire pumps; ibinebenta katabi ng sister brand na HaleNabili

Fireman's outfits at firefighter PPE

4
VIKING Life-Saving EquipmentVIKING Life-Saving EquipmentDenmark
  • MSA BristolMSA Safety · United KingdomMga structural, USAR at wildland firefighter garment na tinahi sa Bristol; ang dating Bristol UniformsNabili
  • TexportAustria
  • Wolf Safety LampUnited Kingdom

Inert gas at nitrogen generators

3
SurvitecSurvitecUnited Kingdom
  • Maritime ProtectionSurvitec · NorwayKristiansand inert gas, flue gas at nitrogen generators; ang pinangalanang specialist ng SurvitecNabili
  • Alfa Laval Smit Inert GasAlfa Laval · NetherlandsMga inert gas at flue gas generator para sa tanker; ang dating Smit Gas SystemsNabili

High-pressure cylinders at cylinder valves

3
  • Luxfer Gas CylindersLuxfer Group · United KingdomAluminium at composite na SCBA at life-support cylinders; ang Luxfer Group na nakalista sa NYSENabili
  • Faber IndustrieItaly
  • Rotarex FiretecLuxembourg

Passive fire protection at insulation

3
  • ROCKWOOLDenmark
  • PromatEtex Group · BelgiumMga passive fire protection board at spray mula sa Tisselt, kabilang ang marine sa mga merkado nitoNabili
  • Morgan Thermal CeramicsMorgan Advanced Materials · United KingdomMga FireMaster Marine wrap para sa A-class deck at bulkhead; DNV at MED certifiedNabili

Ang mga mark ay ipinapakita sa sarili nilang mapusyaw na background, hindi binago, at pag-aari ng kani-kanilang may-ari. Tinutukoy ng isang mark dito ang equipment na saklaw ng gawaing ito. Hindi ito nangangahulugan ng anumang endorsement, awtorisasyon o pag-apruba sa ShipCertify ng may-ari nito.

17 sa 185 na mark ang nakatala